Change Language
Dielectric Constant And Dissipation Factor Testing Services

Dielectric Constant And Dissipation Factor Testing Services

Product Details:

  • Power 230V AC, 50Hz (lab power supply)
  • Interface Laboratory testing unit, digital data interface
  • Size Custom/varies as per requirement
  • Measuring Range Dielectric constant: 11000+, Dissipation factor: 0.00011
  • Driven Type Electrical, automatic/manual test setups
  • Temperature Ambient to elevated (typically 20C to 150C, as per test standards)
  • Material Insulating materials, electrical samples
  • Click to view more
X

Dielectric Constant And Dissipation Factor Testing Services Price And Quantity

  • 1 Piece
  • Digital data available, test report documentation provided
  • IEC, ASTM, IS, and other international dielectric test standards
  • On-site or laboratory testing
  • Typically 17 working days
  • Performed by qualified technical staff, certified laboratory
  • Traceable to national/international standards
  • Precision LCR meters, automatic dielectric testers
  • Dielectric constant (Permittivity), Dissipation Factor (Tan Delta) measurement
  • Testing conducted in controlled temperature and humidity
  • Compliant with high-voltage laboratory safety protocols
  • Solid sheets, liquids, cables, polymer films, capacitor samples

Dielectric Constant And Dissipation Factor Testing Services Product Specifications

  • 230V AC, 50Hz (lab power supply)
  • Custom/varies as per requirement
  • Laboratory testing unit, digital data interface
  • Dielectric constant: 11000+, Dissipation factor: 0.00011
  • Electrical, automatic/manual test setups
  • Ambient to elevated (typically 20C to 150C, as per test standards)
  • Insulating materials, electrical samples
  • Varies based on sample size
  • Digital readout, graphical display
  • Standard test voltages up to 10 kV AC (depending on sample and test method)
  • Testing of dielectric constant and dissipation factor for electrical insulation materials, capacitors, cables, electronic components
  • Power frequency (50/60 Hz), optionally up to 1 MHz
  • Digital data available, test report documentation provided
  • IEC, ASTM, IS, and other international dielectric test standards
  • On-site or laboratory testing
  • Typically 17 working days
  • Performed by qualified technical staff, certified laboratory
  • Traceable to national/international standards
  • Precision LCR meters, automatic dielectric testers
  • Dielectric constant (Permittivity), Dissipation Factor (Tan Delta) measurement
  • Testing conducted in controlled temperature and humidity
  • Compliant with high-voltage laboratory safety protocols
  • Solid sheets, liquids, cables, polymer films, capacitor samples

Dielectric Constant And Dissipation Factor Testing Services Trade Information

  • AHmedabad
  • Cash Advance (CA), Cash in Advance (CID)
  • 1 Piece Per Day
  • 7 Days
  • No
  • Contact us for information regarding our sample policy
  • Any
  • Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa
  • All India
  • ISO

Product Description

We are offering an exclusive Dielectric Constant And Dissipation Factor Testing Services.

Our highly experienced professionals use the best qualitytools and high-end technology. Being a leader in the industry, This service iscarried out under the supervision of our experts who maintain all the qualitystandards prescribed by leading industry. To cater this service, The offeredservice is highly acknowledged by our clients owing to its flawlessness andhassle-free execution.



Comprehensive Testing Solutions

We employ advanced instrumentation and rigorous protocols to test dielectric constant (permittivity) and dissipation factor (tan delta) across a broad spectrum of materials and sample formats. Our services cater to research, manufacturing, and quality assurance for electrical insulation, capacitors, cables, and polymers, adhering strictly to international and national standards.


Reliable Data and Detailed Reporting

Clients receive digital data outputs along with meticulous test report documentation. Every measurement is conducted under controlled temperature and humidity conditions, using high-voltage safety procedures with calibration traceable to recognized standards. Our reports provide valuable insights for product development, compliance, and troubleshooting.


Flexible and Efficient Service Delivery

We offer both laboratory-based and on-site testing, adapting to various client needs and sample sizes. Typical turnaround times range from 1 to 7 working days, ensuring timely results without compromising quality. Our expert technical team ensures accuracy and reliability throughout the testing process.

FAQ's of Dielectric Constant And Dissipation Factor Testing Services:


Q: How is dielectric constant and dissipation factor testing performed?

A: Testing uses precision LCR meters and automatic dielectric testers, applying test voltages up to 10 kV AC and frequencies between power frequency (50/60 Hz) up to 1 MHz. Samples are conditioned under controlled temperature and humidity, and both parameters are measured according to IEC, ASTM, IS, or other applicable standards.

Q: What types of samples can be tested for dielectric properties?

A: We accommodate a wide range of sample forms, including solid sheets, liquids, cables, polymer films, and capacitor samples. The sample size and weight are flexible and dependent on the specific requirements of the customer or test standard.

Q: When and where can the testing services be availed?

A: Testing is available throughout India, either at our certified laboratories or on-site at the client's location. We strive to deliver results within 1 to 7 working days from receipt of the samples and test specifications.

Q: What does the test report include, and what kind of data output can clients expect?

A: Clients receive digital data output and detailed test report documentation. The reports include measured dielectric constant, dissipation factor (tan delta), test conditions, methodology, instrument calibration details, and results interpretation.

Q: How is quality assurance maintained during the testing process?

A: All tests are conducted by qualified technical staff in certified laboratories, with calibration traceable to national or international standards. High-voltage laboratory safety protocols and rigorous quality control measures ensure reliability and repeatability of results.

Q: What are the benefits of dielectric constant and dissipation factor testing for electrical materials?

A: Testing reveals essential electrical insulation properties, helping manufacturers choose suitable materials, verify compliance, enhance product reliability, and troubleshoot potential failure modes. It is invaluable for applications in capacitors, cables, electronic components, and insulating materials.

Q: Which international test standards do your services conform to?

A: We perform dielectric testing in strict conformity with IEC, ASTM, IS, and various other applicable international dielectric test standards, as specified by client or industry requirements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Petroleum Testing Services.' category



We Provide Our Testing Services in India, Africa, USA, and Canada.

All The Clients Are Requested To Send Their Samples Through Courier Only, As We Will Not Be Able To Entertain Any Client At The Lab.

Back to top