Change Language
DGA Testing Services

DGA Testing Services

199 INR/Piece

Product Details:

  • Usage & Applications Determination of Dissolved Gas in Transformer Oil, Detection of Transformer Faults
  • Temperature Ambient
  • Size Custom
  • Display Digital
  • Voltage 230 V AC
  • Interface Lab Analytical Equipment
  • Power 230 W
  • Click to view more
X

DGA Testing Services Price And Quantity

  • 1 Piece
  • 199 INR/Piece
  • Approx. 2 hours
  • 2-5 ml
  • GC (Gas Chromatography)
  • Tabular and Graphical
  • 2%
  • Syringe/Vial
  • Hydrogen, Methane, Ethylene, Ethane, Acetylene, Carbon Monoxide, Carbon Dioxide
  • Onsite/Offsite

DGA Testing Services Product Specifications

  • 50 Hz
  • Standard
  • Manual/Semi-Automatic
  • Transformer Oil
  • 1 to 10000 ppm
  • Determination of Dissolved Gas in Transformer Oil, Detection of Transformer Faults
  • Ambient
  • Custom
  • 230 V AC
  • Digital
  • Lab Analytical Equipment
  • 230 W
  • Approx. 2 hours
  • 2-5 ml
  • GC (Gas Chromatography)
  • Tabular and Graphical
  • 2%
  • Syringe/Vial
  • Hydrogen, Methane, Ethylene, Ethane, Acetylene, Carbon Monoxide, Carbon Dioxide
  • Onsite/Offsite

DGA Testing Services Trade Information

  • Ahmedabad
  • Cash Advance (CA), Cash in Advance (CID)
  • 7 Days
  • Contact us for information regarding our sample policy
  • Any
  • Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa
  • All India
  • ISO

Product Description

We are offering an exclusive DGA Testing Services.

Our highly experienced professionals use the best qualitytools and high-end technology. Being a leader in the industry, This service iscarried out under the supervision of our experts who maintain all the qualitystandards prescribed by leading industry. To cater this service, The offeredservice is highly acknowledged by our clients owing to its flawlessness andhassle-free execution.



Precision Analysis for Transformer Health

Our DGA Testing Services provide a highly accurate method to detect trace levels of gases dissolved in transformer oil, critical for early identification of transformer faults. Utilizing advanced laboratory analytical equipment, we ensure high precision and quick turnaround, enabling timely maintenance decisions and helping to prevent costly breakdowns in electrical infrastructure.


Flexible Sample Collection and Reporting

Samples can be collected in syringes or vials and analyzed either at your location (onsite) or in our laboratories (offsite). Detailed results are provided in both tabular and graphical formats, ensuring that technical teams can easily interpret the data for actionable insight, supporting comprehensive transformer oil analysis and condition assessment.

FAQs of DGA Testing Services:


Q: How is the DGA testing using Gas Chromatography performed on transformer oil samples?

A: The Dissolved Gas Analysis (DGA) is conducted by extracting a 25 ml sample of transformer oil using a syringe or vial. This sample is introduced into a Gas Chromatography (GC) system, where gases such as hydrogen, methane, ethylene, ethane, acetylene, carbon monoxide, and carbon dioxide are separated and measured for precise quantification.

Q: What types of transformer faults can DGA testing help detect?

A: DGA testing can help identify thermal and electrical faults in transformers by detecting abnormal levels of key gases dissolved in the oil. Early detection of gases like acetylene or ethylene indicates issues such as overheating, arcing, or insulation breakdown, allowing for preventative maintenance before severe damage occurs.

Q: When should DGA testing services be used for transformer oil monitoring?

A: It is recommended to use DGA testing during routine maintenance, after transformer overloading, or when there is a suspicion of internal fault based on operational anomalies. Periodic testing helps track the condition of transformers and prevent unexpected failures.

Q: Where can DGA testing services be performed?

A: Our DGA testing services can be provided both onsite at your transformers location or offsite at our analytical laboratory facilities. This flexibility ensures minimal disruption to operations and quicker access to diagnostic information.

Q: What is the process for submitting a sample for DGA testing?

A: Collect a 2-5 ml transformer oil sample using a syringe or vial, ensuring that the container is clean and airtight. The sample can then be shipped or handed over to our service team for prompt analysis, and results are typically available within approximately 2 hours after receipt.

Q: How can the results of DGA testing benefit transformer operations?

A: The results from DGA testing provide detailed insight into the health and condition of the transformer. Early detection of dissolved gases enables targeted maintenance actions, helping extend transformer lifespan, reduce unplanned outages, and optimize asset management strategies.

Q: What formats are used to report DGA test results?

A: DGA test results are delivered in both tabular and graphical formats, making it straightforward for electrical engineers and maintenance teams to interpret trends, compare with industry thresholds, and make informed decisions regarding transformer maintenance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Petroleum Testing Services.' category



We Provide Our Testing Services in India, Africa, USA, and Canada.

All The Clients Are Requested To Send Their Samples Through Courier Only, As We Will Not Be Able To Entertain Any Client At The Lab.

Back to top